#68: Oscilloscope Probe Ground lead length effects on signal quality

w2aew
w2aew
45.1 هزار بار بازدید - 12 سال پیش - This video illustrates the effects
This video illustrates the effects that the scope probe's ground lead or ground wire length can have on the integrity of the signal that you measure.  The ground wire introduces unwanted inductance into the probe measurement path.  This inductance will affect the high frequency content of the signals being measured.  For digital signals, this most often results in overshoot and ringing associated with the rising and falling edges of the signals.  The faster the rise/fall time of the signal, the more it will be affected by the probe's ground inductance.  The video goes through two signal examples, one from a signal generator, and one from an integrated 30MHz CMOS crystal oscillator.  The affects of the different ground lead lengths are dramatically shown on the scope.
12 سال پیش در تاریخ 1391/09/16 منتشر شده است.
45,127 بـار بازدید شده