#143: Transmission Line Terminations for Digital and RF signals - Intro/Tutorial

w2aew
w2aew
165.9 هزار بار بازدید - 10 سال پیش - An introduction to why and
An introduction to why and when terminations are needed for transmission lines in both high speed digital applications and RF applications.  50 ohm termination examples are given, but the principles apply for other line impedances as well. The basic operating principles of signal propagation down a transmission line and the effects of reflections coming from improperly terminated are covered.  Examples for digital-like signals as well as RF signals are given. A description and examples of what is meant by Standing Waves is also given. As a bonus, the properties of quarter wavelength transmission lines in RF applications is also presented. Notes from the video can be found here:
http://www.qsl.net/w/w2aew//youtube/T...