Boiler Blow Down Procedure | Scum and Bottom Blow Down

Sailor Imran
Sailor Imran
11.4 هزار بار بازدید - 2 سال پیش - The following steps should be
The following steps should be taken to blow down a boiler.

Open the quick-opening valves (ones closest to the boiler). Valve 2 and valve 4

Open the slow-opening valve. Valve 3 and Valve 5

Blow down the boiler for the amount of time specified by your water management consultant by opening and then closing the slow-opening valve. Pay close attention to the water level in the gauge glass. Some loads require several, short blowdown cycles to maintain the proper water level in the boiler System

Close the slow-opening valve.

Close the quick-opening valve(s).

Open the slow-opening valve again to drain the line between the quick and slow-opening valves.

Close the slow-opening valve again and double check that the shutoff is tight after the valve has cooled off