ASTM C1064 - ACI Concrete Temperature Test 2019

SI Certs
SI Certs
29 هزار بار بازدید - 5 سال پیش - Temperature of Freshly Mixed Hydraulic-Cement
Temperature of Freshly Mixed Hydraulic-Cement Concrete
ACI Technician Workbook CP-1

------------------------------------------------------------------

* Temperature Measuring Device (TMD) Requirements *

The thermometer in use must adhere to the following requirements:

- Measure to within +/- 1 degree Fahrenheit
- Measuring device must read between 30 to 120 degrees
- Have 3-inches concrete cover in all directions
- Be inserted a minimum of 3-inches
- Be left in concrete a minimum of 2 min., maximum of 5 min.
- Be calibrated annually, or if there’s a question of accuracy
- Not vary by more than 1 degree Fahrenheit when verified against a reference thermometer

------------------------------------------------------------------

Want to pass a special inspection exam? Enroll in an online ICC course today:

https://sicerts.com/courses
5 سال پیش در تاریخ 1398/03/02 منتشر شده است.
29,048 بـار بازدید شده
... بیشتر