35.4 هزار بار بازدید - 2 سال پیش - Today, we’ll show you the
Today, we’ll show you the steps in rebuilding an unloader valve.  

When rebuilding the unloading valve, you need to inspect and clean all components.

As part of the rebuild inspect and clean the inside bore and the pinhole for the condensate drain.

Replace the piston seal as well as the seal on the unloading valve plunger.

A new plunger is included as part of the rebuild kit.

As part of the rebuild the blow down valve O-rings should also be replaced.

Inspect the blow down valve for any damage, if damaged it must be replaced.

After the valve is cleaned and resealed it is ready to be put back on the unit.

Atlas Copco USA is an industry-leader in the sales and service of industrial gas and air compressors, parts and service, vacuum pumps and construction equipment including mobile compressors, pumps, light towers, generators, handheld tools, Industrial electric, pneumatic, cordless transducerized assembly tools, alongside an extensive range of pneumatic grinders, sanders, chipping hammers and riveting systems.