NO CRANK NO START AFTER STARTER REPLACED! Diagnostic Steps To Help Find The Root Cause Of No Crank
109.8 هزار بار بازدید -
4 سال پیش
-
Starter Motors are a common
Starter Motors are a common failure but this component is often misdiagnosed. The incorrect diagnosis often occurs on X3 vehicles. I had a subscriber reach out to me asking for help after replacing the starter and then after a short time ended up with another no crank situation. I show you how to perform voltage and voltage drop testing and a quick way to check to see if the underlying problem is a corroded engine ground strap.
I would recommend the bulb style circuit tester. The LED digital ones cannot check amperage. Using the bulb style tester you can detect a dim light which would denote a loss of amperage.
As an Amazon Influencer, I earn from qualifying purchases. I only recommend products I feel will provide the best benefit to you.
Bulb Style Test Light
https://amzn.to/3NMo4n3
I would recommend the bulb style circuit tester. The LED digital ones cannot check amperage. Using the bulb style tester you can detect a dim light which would denote a loss of amperage.
As an Amazon Influencer, I earn from qualifying purchases. I only recommend products I feel will provide the best benefit to you.