NAD C352 Amplifier Repair (With Audio Tutorial)
1.1 هزار بار بازدید -
9 ماه پیش
-
FaultIntermittent start up and CD
Fault
Intermittent start up and CD selection LED not illuminating.
Amplifier re-capped and replacement 5 mm 2-volt Green LED installed.
For further information about capacitors watch this tutorial
Capacitors used in Audio Amplifiers E...
Speaker protection relay replaced due to the age of the Amplifier.
24 V DC Coil DPST
Dry solder joints reflowed, and user controls and switches cleaned with
De-Oxit to ensure noise free operation.
DC offset and bias for both channels adjusted back to factory setting.
Amplifier fully tested working correctly.
Intermittent start up and CD selection LED not illuminating.
Amplifier re-capped and replacement 5 mm 2-volt Green LED installed.
For further information about capacitors watch this tutorial
Capacitors used in Audio Amplifiers E...
Speaker protection relay replaced due to the age of the Amplifier.
24 V DC Coil DPST
Dry solder joints reflowed, and user controls and switches cleaned with
De-Oxit to ensure noise free operation.
DC offset and bias for both channels adjusted back to factory setting.
Amplifier fully tested working correctly.
9 ماه پیش
در تاریخ 1402/08/20 منتشر شده
است.
1,160
بـار بازدید شده