SALADETTES SAG - DIXELL DISPLAY WORK PARAMETERS - GGM GASTRO

GGM Gastro Support
GGM Gastro Support
676 بار بازدید - 4 سال پیش -
https://www.ggmgastro.com/gb/

In this video we explain the factory parameters of the SAG series saladettes, if they are equipped with a Dixell display.

The work in our videos is carried out by an expert. All explanations as well as executions are only a recommendation of the providers.

__________________________________________________________________________

► ABOUT THIS CHANNEL

On "GGM Gastro Support" helpful explanatory videos appear regularly in which we solve technical problems or ambiguities. It is important to us that our products are understood by our customers and can be used without any problems. With "GGM Gastro Support" we would therefore like to answer all technical questions in order to guarantee maximum support.

__________________________________________________________________________

► ABOUT THE PRODUCT

Mini saladettes SAG 700: https://www.ggmgastro.com/gb/kuhlung/...

Saladettes SAG 700: https://www.ggmgastro.com/gb/kuhlung/...

Mini preparation tables SAS: https://www.ggmgastro.com/gb/kuhlung/...

HY
HY stands for hysteresis, the factory setting is 2°C, which means for example
The article cools down to 4°C and then switches off the compressor. When the temperature reaches 6°C, the compressor starts again. So the hysteresis is always added to the set temperature.

LS
LS means "Lower Setpoint", the lowest adjustable setpoint. This is set to 0 in the AGG top-mounted showcases at the factory.

US
US means "Upper Setpoint", i.e. the highest adjustable setpoint. This is set to 10 in the SAG series saladettes.

OT
The OT parameter is used to calibrate the room sensor. Here, the set value is added to the measured value or subtracted from the value. For the AGG top display cases, the standard value is -1.

OD
OD is the control delay in minutes. The factory setting is 2, which means that the controller starts controlling two minutes after power-on.

AC
AC is the anti-sway protection for the compressor. This parameter determines the minimum switch-off time of the compressor in minutes, factory setting here: 2 minutes

ID
The ID value controls the defrosting interval (i.e. after how many hours defrosting will take place).
Factory setting would be 6, which means that the article defrosts every 6 hours.

MD
MD indicates how long the article will defrost (in minutes), the factory setting is 20, which means that the article will defrost for a maximum of 20 minutes and then start to cool down again.

Our webshop: https://www.ggmgastro.com/gb/

__________________________________________________________________________

► MORE HELPFUL VIDEOS

To the last explanation video: MICROWAVE MWM3414  - REPLACING DOOR -...

To the complete overview:
@ggmgastrosupport

__________________________________________________________________________

► GGM GASTRO ON SOCIAL MEDIA

WhatsApp: https://www.ggmgastro.com/whatsapp

Facebook: Facebook: ggmgastro

Twitter: Twitter: ggmgastro

Instagram: Instagram: ggmgastro

Linked In: LinkedIn: ggmgastro

TikTok: https://www.tiktok.com/@ggmgastro?lan...
4 سال پیش در تاریخ 1399/08/22 منتشر شده است.
676 بـار بازدید شده
... بیشتر