DSC pC1832 Program zones to partitions

家華安防 programming made simple
家華安防 programming made simple
3.6 هزار بار بازدید - 2 سال پیش - 1. Programming Zone Definitions *8
1. Programming Zone Definitions
*8 code
Section [001] – Zones 1 to 16
Section [002] – Zones 17 to 32
Section [003] – Zones 33 to 48
Section [004] – Zones 49 to 64
2. Partition Zone Assignment
zones are assigned to additional partitions, ensure the partitions are enabled in
Section [201].
Zones will not function until they are enabled. Enable all zones being used by turning ON the
appropriate option in Section [202] to [265].
Section [202] – [209] Partition 1 zones 1 to 64 enable/disable
Section [210] – [217] Partition 2 zones 1 to 64 enable/disable
Section [218] – [225] Partition 3 zones 1 to 64 enable/disable
Section [226] – [233] Partition 4 zones 1 to 64 enable/disable
Section [234] – [241] Partition 5 zones 1 to 64 enable/disable
Section [242] – [249] Partition 6 zones 1 to 64 enable/disable
Section [250] – [257] Partition 7 zones 1 to 64 enable/disable
Section [258] – [265] Partition 8 zones 1 to 64 enable/disable