Troubleshoot: Water Well Pump Overloads Tripping

R.C. Worst & Co., Inc.
R.C. Worst & Co., Inc.
192 هزار بار بازدید - 7 سال پیش - In the event that the
In the event that the motor runs but the overload protector trips here are the things to look out for:

Incorrect Voltage - Check your power source, be sure to check that power is getting through to the system, it is recommended that you check voltage at the pressure switch and also the control box, basically you want to check that power is getting all the way through the system and any components that power is running through. I usually will start by checking voltage at the pump control panel and work my way from there. Your voltage needs to be +/- 10% of motor rating. If you find that your voltage is too high/low at the breaker panel you may need to contact the power company.
Overheated Protectors - If the box is mounted outdoors in direct sunlight or other heat sources can cause the overloads to overheat and prevent the pump from operating. Shading the box or moving it may be necessary.

Defective Control Box - The control box may have malfunctioned. Your previous voltage checks may have already led you to this conclusion, but if you would like detailed instructions on troubleshooting your control box we are adding those videos later in this series. But generally speaking, a visual inspection of the components is recommended as often times parts that fail will appear burnt. It is possible to replace individual components inside the panel but the components are expensive so if the box is over 10 years old replacement is recommended.

Finally, if everything else seems good, it may be time to replace the pump. Fortunately, there are a number of checks that you can perform to determine if the pump or wiring down the well is bad and needs to be pulled from the well. We will go over these troubleshooting methods in part 4 of this troubleshooting series. It is possible for poor connections down the well to cause the motor to appear bad so if you do end up pulling the well check the motor again to be sure it is the pump and motor, not the wiring connection. Replacement of the pump and motor or wire may be necessary, I advise you strongly consider replacing the pump end along with the motor if the pump is older than 5 years and the motor has failed.


If you need more information or assistance with products, call 855.329.4519 or email [email protected] to speak with an industry expert. Thanks for watching!

Add us to your professional network: https://www.linkedin.com/company-beta...

Follow us on Twitter: Twitter: rcworst

Like us on Facebook: Facebook: rcworst

For more industry videos visit our YouTube Channel: @rcworstwater

Check out our website: https://www.rcworst.com/

We are a distributor of pumps, packaged pumping systems, on-site wastewater treatment equipment, on-site wastewater treatment systems, and custom electrical control panels for water and wastewater applications, water well supplies, drilling supplies, and water treatment equipment.
7 سال پیش در تاریخ 1396/07/13 منتشر شده است.
192,007 بـار بازدید شده
... بیشتر