DIGSI 5 Setup
Additional Steps upon First Time Use of DIGSI 5
DIGSI 5 startup
DIGSI 5 and SIPROTEC 5 Vs. DIGSI 4 and SIPROTEC 4
User Interface, Project, and Project Tree
Creating a topology as a single-line configuration
Incorporating SIPROTEC 5 devices into the topology
Configuring hardware of a SIPROTEC 5 device
Defining the functional scope of a SIPROTEC 5 device
Defining individual function settings
Routing information
Editing display pages
Configuring function charts (CFC)
Configuring the communication network and setting communication settings
Displaying saved measured values and indications
Displaying saved fault records and evaluating them with SIGRA
Exporting and printing data
Creating test sequences
Transmitting settings values from DIGSI 5 to the SIPROTEC 5 device
Transmitting settings values from the SIPROTEC 5 device to DIGSI 5 and saving them in files
Transmitting indications, measured values, and fault records from the SIPROTEC 5 device to DIGSI 5 and saving them in files
Setting limiting values
Testing SIPROTEC 5 devices and functions
Controlling equipment
Initial startup or restart of the SIPROTEC 5 device
Setting the date and time of the SIPROTEC 5 device
Several versions of one device type
Working Offline and Online with SIPROTEC 5 device
Managing Device Drivers
Firmware for SIPROTEC 5 devices
Firmware for communication modules
Communication protocols
Communication mappings
Checking for New DIGSI 5 Version
Library elements
Elements for the hardware catalog
Selecting an application template
Open the DIGSI 5 Information Routing to route information with complete details
Open the DIGSI 5 Display Editor to edit display pages with complete details
Open the DIGSI 5 Function-Chart (CFC) Editor to configure additional functions such as interlockings with complete details
Open the DIGSI 5 Network View to configure a communication network with complete details
Display saved measured values and indications in DIGSI 5 and SIPROTEC 5 with complete details
Display saved fault records in DIGSI 5 with complete details
Export and print data in DIGSI 5 with complete details
Transfer indications, measured values, and fault records from the SIPROTEC 5 device to DIGSI 5 with complete details
Test SIPROTEC 5 devices and functions using the test suit in DIGSI 5 with complete details
Control Equipment with complete details
Find and edit SIPROTEC 5 devices connected to a network with complete details
Config and parameters of the SIPROTEC 5 Overcurrent protection phases 50/51
Config and parameters of the SIPROTEC 5 Overcurrent protection, ground 50N/51N
Config and parameters of the SIPROTEC 5 Directional overcurrent protection 67
Config and parameters of the SIPROTEC 5 Negative sequence 46
Config and parameters of the SIPROTEC 5 Voltage-dependent overcurrent protection 51V
Config and parameters of the SIPROTEC 5 Directional overcurrent protection, ground 67N
Communication mapping
Device settings
Time settings
Power system data
Measuring points info and settings
Fault recorder settings
CT connection types
VT connection types
Circuit-breaker function group
Voltage-current 3-phase function group
Entering settings based on secondary, primary, or percent
Current-flow criterion:
Closure detection:
Current thresh. CB open parameter
Output time parameter
Blk. Op. Ind. Fault Rec. parameter
Reference value parameter
Current limitation Imax parameter
7SJ8x Overcurrent Protection Functions
SIPROTEC relay families with the features and applications
SIPROTEC 7SX800
SIPROTEC 5 family
Browser-based user interface
Checking and adjusting the values of a specific setting
Comparing the values of 2 or more devices
Checking a setting value against a user-defined setting to verify whether the setting value differs from the default value specified by Siemens
Querying a value in order to adjust a test case, for example to preset the tripping current